The tool looks up a base capacity from floor area in square feet, for example 5,000 BTU/h up to 150 ft², 6,000 up to 250 ft², 9,000 up to 400 ft² and 18,000 up to 1,000 ft². It scales up for ceilings above 8 ft, multiplies by 0.9 for shaded or 1.1 for sunny rooms, adds 600 BTU/h for each person beyond two, and rounds up to the next 500. One cooling ton is 12,000 BTU/h, and 1 BTU/h ≈ 0.293 W.
A 12 × 15 ft room (180 ft²) with 8 ft ceilings, normal sun and two people: 6,000 BTU/h, about 0.5 tons or 1.76 kW. A sunny room needs 7,000 BTU/h; four occupants raise it to 7,500 BTU/h, and so does a 10 ft ceiling.
Average power = rated power × compressor duty cycle; daily energy = average power × hours per day ÷ 1000; period energy = daily energy × days. For example 900 W at a 60% duty cycle, 8 hours a day for 30 days: 540 W average, 4.32 kWh a day, 129.6 kWh a month, about 25.92 at a rate of 0.20.
Not necessarily. An oversized unit short-cycles, removes less humidity and can feel clammy while using more energy. Choose a size close to the estimate and adjust for insulation, orientation and climate.
12,000 BTU/h = 1 ton ≈ 3.52 kW of cooling. Some markets also use horsepower ratings, which vary by brand, so check the cooling capacity on the rating plate.
Kitchens add heat from cooking; a common rule is to add about 4,000 BTU/h. Open-plan living areas should be sized for the combined connected area. The tool does not add a kitchen load automatically.
Above 2,500 ft² (about 232 m²) or ceilings over 20 ft, rules of thumb become unreliable. A load calculation such as Manual J that accounts for insulation, windows, ventilation and climate is needed.
This tool estimates the cooling capacity of an air conditioner in a single room and estimates electricity usage by nameplate rating. It is not used for heating or whole-house equipment selection; actual power consumption is also affected by frequency conversion regulation, outdoor temperature, insulation, set temperature and electricity price structure.