Choose two known quantities
Select two independent positive amplitudes from V, I, R, and P to derive the remaining two quantities.
Please enter a finite value greater than 0.
Default case calculated: 12 V, 6 Ω, 2 A, 24 W.
Four readings
Orange is the known quantity this time, and the rest are derived quantities.
P = V² / R = 12² / 6 = 24 W
Simplify the circuit
It only expresses the amplitude relationship between the ideal DC power supply and pure resistance.
P here is the dissipated power in the ideal resistor model, not the component power rating, recommended wattage or safety selection conclusion.
Current formula path
Show how to substitute known quantities this time, rather than just giving the final number.
I = V / R
P = V × I = V² / R
Check: P = I² × R
Six sets of solutions
There are six independent combinations of any two of the four quantities.
| known quantity | Derived quantity |
|---|---|
| V + I | R = V / I; P = V × I |
| V + R | I = V / R; P = V² / R |
| V + P | I = P / V; R = V² / P |
| I + R | V = I × R; P = I² × R |
| I + P | V = P / I; R = P / I² |
| R + P | I = √(P / R); V = √(P × R) |
Verifiable example
Default case: 12 V and 6 Ω gives 2 A and 24 W, cross-check with P=VI or P=I²R.
Prefix example: 12 mV with 6 kΩ gives 2 µA and 24 nW; changing the prefix does not change the underlying physical quantity.
Calculation method
The page first converts the input and prefix to basic SI values, and then solves the problem according to the selected combination. Unrounded double-precision numbers are used internally, and the display retains 6 significant digits; the results can be cross-checked with V=IR and P=VI.
Model limitations
The model ignores AC phase, temperature rise, tolerances, starting current, non-ohmic behavior, power supply internal resistance, and conductor losses. All quantities must be positive in magnitude, and basic SI input and derived results are limited to 1e-12 to 1e12.
real circuit boundaries
Do not use this page to select component ratings, wires, fuses, circuit breakers, or wiring methods. Realistic circuits should be consulted with component data sheets, local codes and field measurements, and should be judged by qualified personnel.
All input and calculations are only processed locally in the browser, no data is uploaded.